Power Meter Power Sensor Special Options
This selection guide comprises the common power sensor special options (including Thermistor Mount).
For further information on power meter and power sensor specials, contact your local Keysight FE or sales office.
Special Options
Thermistor Mounts | Description |
---|---|
478A-H13 |
Frequency range 100 KHz to 1 GHz, max SWR 1.8 to 300 KHz, 1.3 to 1 GHz, std lab cal at 13 frequencies |
478A-H55 | Frequency range 1 MHz to 1 GHz, max SWR 1.3 |
478A-H63 | Frequency range 100 kHz to 1 GHz, max SWR 1.8 to 300 kHz, 1.3 to 1 GHz |
478A-H72 | Frequency range 1 MHz to 1 GHz, max SWR 1.2 |
478A-H73 | Frequency range 1 MHz to 100 MHz, max SWR 1.1 except 1.05 at 50 MHz |
478A-H75 | Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz |
478A-H76 | Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz. Std lab cal at 50 MHz |
478A-H83 | 1 MHz to 1 GHz, SWR 1.05 at 50 MHz. Std lab cal 1, 3, 10, 30, 50, 100, 300, 1000 MHz |
478A-H93 | Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz. Std lab cal at 50 MHz and 100 MHz |
8478B-H01 | VSWR at or less than 1.05 at 50 MHz |
8478B-H27 | Standards lab cal at 9 MHz |
8478B-H48 | Improved VSWR equal to 1.2:1 from 1 to 12 GHz; 1.34:1 from 12 to 18 GHz |
8478B-H84 | Std lab cal at specified frequencies |
E-Series Sensors | Description |
E4413A-H33 | Specified performance for 50 MHz to 33 GHz |
E9300A-H25 | Power level -50 to +30 dBm (APC 3.5(m) connector) |
E9300B-H01 | Power Sensor-Average, 10 MHz to 18 GHz, -30 to +46.1 dBm |
E9301B-H01 | Average input power to 100 watts (+50dBm) to 4.2 GHz only |
E9304A-H18 | Frequency range 9 kHz to 18 GHz, -60 to +20 dBm |
E9304A-H19 | Frequency range 9 kHz to 18 GHz, -50 to +30 dBm |
E9304A-H20 | Frequency range 9 kHz to 18 GHz, -60 to +20 dBm, APC 3.5mm |
E9304A-H84 | Average Power, 9 kHz to 18 GHz, -60 To +20dBm, N-type, std lab cal at specified frequencies |
P-Series Meters | Description |
N1911A-H01 | Include video output |
N1912A-H01 | Include video output |
P-Series Sensors | Description |
N1921A Option C35 | Frequency range 50 MHz to 18.5 GHz ( 3.5 mm male input connector) |
N8480 Series | Description |
N8481A-H02 | DC Coupled Sensor 10 MHz to 18 GHz, -35 dBm to +20 dBm |
N8481A-H84 | Average Power, 10 MHz to 18 GHz with 1 GHz steps, -35 dBm to +20 dBm, N-Type,STD lab cal |
N8481B-H84 | Average Power, 10 MHz to 18 GHz, 0 to +44dBm, N-type, Std lab cal at specified frequencies |
N8481H-H84 | Average Power, 10 MHz to 18 GHz, -10 dBm to 35 dBm, N-type, Std lab cal at specified frequencies |
N8482A-H02 | DC Coupled Sensor 100 kHz to 6 GHz, -35 dBm to +20 dBm |
N8482A-H84 | Average Power, 100 kHz to 6 GHz, -35 dBm to +20 dBm, N-type, standard lab calibration |
N8482B-E01 | Power Sensor bundled solution |
N8482B-H84 | Average Power, 10 kHz to 4.2 GHz, 0 to +44 dBm, N-type, Std lab cal at specified frequencies |
N8482H-H84 | Average Power, 100 kHz to 4.2 GHz, -10 dBm to 35 dBm, N-type, Std lab cal at specified frequencies |
N8485A-H02 | DC Coupled power sensor that allows excellent low- frequency coverage including DC signal |
N8485A-H84 | Average Power,10 MHz to 26.5 GHz, -35 dBm to +20 dBm,3.5mm (male), Std lab cal at specified frequencies |
N8487A-H02 | DC Coupled power sensor that allows excellent low- frequency coverage including DC signal |
N8487A-H84 | Average Power,50 MHz to 50 GHz, -30 dBm to 20 dBm, 2.4mm (male), Standard lab calibration |
U2000 Series | Description |
U2001A-H03 | USB Power Sensor, 3 MHz to 6 GHz |
U2001A-H16 | USB Power Sensor 10 MHz to 6 GHz with 1 kOhm external trigger impedance |
U2002A-H26 | USB Power Sensor, 10 MHz to 26.5 GHz |
U2022XA-H50 | USB Wideband Power Sensor (50MHz - 50GHz) |
U8480 Series | Description |
U8481A-H86 | DC to 18GHz with improved specification of calibration factor/linearity |
8480 Series | Description |
8481D-H51 | Guaranteed max SWR less than or equal to 1.2 from 18 to 18.5 GHz |
8481D-H84 | Std lab cal at specified frequencies |
8485D-H84 | Std lab cal at specified frequencies |
EPM-P Meters | Description |
E4416A-E20 | Bundle of a E4416A, a E9322A sensor and transit case |
E4416A-E23 | Bundle of a E4416A, a E9322A sensor and carrying case |
E4417A-E01 | Bundle of a E4417A, two E4413A and transit case |
E4417A-E02 | Bundle of a E4417A and two E9327A |
E4416AZ-K01 | Power meter - EPM-P series, single channel with internal rechargeable battery |
E4416AZ-K02 | Retrofit Kit for E4416A to install option 002 (install not included) |
E4417AZ-K01 | Power meter - EPM-P series, dual channel with internal rechargeable battery |
E4417AZ-K02 | Retrofit Kit for E4417A to install option 002 (install not included) |
E4417AZ-K03 | Power meter - EPM-P series, dual channel with Internal Rechargeable Battery - Option 002 and 1A7 |
Waveguides | Description |
E8486A-100 | E-band power sensor, 60 to 90 GHz , -30 dBm to +20 dBm |
E8486A-200 | E-band power sensor, 60 to 90 GHz , -60 dBm to +20 dBm |
E8486A-201 | E-band power sensor, 54 GHz to 95 GHz, -60 dBm to +20 dBm |
V8486A-H01 | Frequency range calibration to 78 GHz |
V8486A-H02 | V-band power sensor, 50 GHz to 75 GHz , -60 dBm to +20 dBm |
V8486A-H100 | V-band power sensor, 50 GHz to 75 GHz , -30 dBm to +20 dBm |
Cables / Adaptor | Description |
E9288AZ-K01 | Power meter test adapter - EPM-P |
Range Calibrator | Description |
11683AZ-K01, K02 | Field upgrade of a standard 11683A range calibrator to 11683AZ-H01 |